Burhans Research Motor Control Systems

Master Line Speed Command

Follower (Slave) Speed Percent

Directions:

  Enter a master speed command in percent, as whole numbers. Maximum speed is 100%. 

  Click "Master Line Speed" to enter the command. 

  Enter a follower speed command in percent, as whole numbers.

  Click "Follower Speed Ratio" to enter the command.

  The follower in this example, can go from 1% of the master's speed, to 2 times (200%) of the master's speed. 

System Basics

This system uses a typical signal output from the master drive, as a speed reference input, to a follower drive.  There is no speed sensing feedback to the drives. The drive speed regulation is "open loop".

Benefits of this system
  • Easy to set up a follower drive, providing it has a suitable input capability

  • Scaling the speed commands of each drive is on board the individual drives.

Drawbacks and Pitfalls of this system
  • When coordinated control is NOT desired, switching to independent control can be complex.

  • Scaling of each drive speed can require running product for a considerable time.

  • The programming of the drives on startup can be complicated.

  • Troubleshooting speed control of each drive can be difficult.

  • Open loop speed regulation may not be adequate.

Basic Bill of Materials for the system shown (excluding power transmission, etc.)
  • 2 vsd's

  • 2 motors

                                                                                    Quick Reference Design Considerations

 

Easy

     

Difficult

  1 2 3 4 5
Set up Complexity   X      
Troubleshoot Complexity     X    
System Operation Flexibility       X  

Speed regulation is often a factor in product quality.

Return to Burhans Research Homepage

Contact: info@burhansresearch.com